Worked example
105 in total rise → 14 risers of 7.5 in
Lay out a staircase that passes code
-
Measure finished floor to finished floor
Measure after the flooring is down, or add its thickness: ½ in of new flooring at the top makes one step that much off, and the IRC allows only ⅜ in between risers.
-
Let it pick the fewest risers
105 in ÷ 14 = 7½ in, the fewest risers at or under the IRC’s 7¾ in limit. Thirteen would be 8 1/16 in, too tall for a US house.
-
Check an English stair against Part K
Approved Document K lets private stairs rise up to 220 mm a step, so the same 105 in climb passes with 13 risers of 8 1/16 in.
-
Squeeze into a short run and see what fails
With only 10 ft of run, 13 treads come out at 9¼ in, under the IRC’s 10 in minimum. The check flags it, so find more space or add a landing.
-
Cut stringers from the layout
√(105² + 130²) = 167.1 in of stringer: a 14 ft 2×12 is 168 in long, leaving under an inch to spare.
Stair code limits
The two codes below are the ones the calculator checks. In the US, states and cities adopt and amend the IRC, so your local building department has the final word. Wales and Scotland have their own regulations.
| Rule (2021 IRC, US) | Limit | Section |
|---|---|---|
| Riser height | not more than 7¾ in (196 mm) | R311.7.5.1 |
| Tread depth | not less than 10 in (254 mm) | R311.7.5.2 |
| Difference between the largest and smallest riser or tread in a flight | not more than ⅜ in | R311.7.5.1, R311.7.5.2 |
| Nosing | ¾ to 1¼ in, not needed where treads are 11 in or deeper | R311.7.5.3 |
| Rise of one flight | not more than 12 ft 7 in between floors or landings | R311.7.3 |
| Landing depth on a straight run | not less than 36 in | R311.7.6 |
| Width | not less than 36 in clear above the handrail | R311.7.1 |
| Headroom | not less than 6 ft 8 in | R311.7.2 |
| Handrail height | 34 to 38 in | R311.7.8.1 |
| Rule (Approved Document K, England) | Private stair |
|---|---|
| Rise | 150 to 220 mm |
| Going | 220 to 300 mm |
| Pitch | not more than 42° |
| 2 × rise + going | 550 to 700 mm |
| Headroom | 2 m (reduced for loft conversions) |
How it works
The total rise is divided into equal risers: by default the fewest that keep each riser at or under the code maximum. A straight stair has one tread fewer than it has risers, because the upper floor is the top step. A landing takes the place of one tread and splits the stair into two flights.
- Riser = total rise ÷ risers
- Treads = risers − 1 (− 1 more for a landing)
- Run = treads × tread depth (+ landing)
- Angle = arctan(riser ÷ tread)
- Stringer = √(rise² + run²) per flight
Worked examples
A 105 in floor-to-floor stair (IRC)
105 ÷ 7.75 = 13.5, so the fewest risers is 14: 105 ÷ 14 = 7.5 in each. With 10 in treads there are 13 treads, a run of 130 in (10 ft 10 in), an angle of 36.9° and a stringer of about 167.11 in.
The same stair with a landing
A 36 in landing after riser 7 replaces one tread: 12 treads, a run of 156 in, and two flights of 7 risers with stringers of about 79.73 in each.
A 2,600 mm stair in England
2600 ÷ 220 = 11.8, so the fewest risers is 12: 216.7 mm each. With 250 mm goings the pitch is 40.9° and 2R + G is 683 mm, both inside the Table 1.1 limits. One more riser gives 200 mm risers, a gentler 38.7° and 2R + G of 650 mm.
Checked with Approved Document K limits
England’s limits for a private stair are in Table 1.1 of Approved Document K. The rise, going, pitch and 2R + G range the calculator checks your stair against are compared with that table each time the page is built. Last run 29 October 2026.
| Example | Where it’s printed | The source’s answer | This calculator |
|---|---|---|---|
| Private stair: rise of each step | Approved Document K, Table 1.1 | 150 to 220 mm | 150 to 220 mm |
| Private stair: going (tread depth) | Approved Document K, Table 1.1 | 220 to 300 mm | 220 to 300 mm |
| Maximum pitch | Approved Document K, Table 1.1 | 42° | 42° |
| Twice the rise plus the going (2R + G) | Approved Document K, Table 1.1 | 550 to 700 mm | 550 to 700 mm |
Questions
What is the maximum riser height?
Under the 2021 IRC, 7¾ inches (R311.7.5.1). Under Approved Document K in England, 220 mm for a private stair (Table 1.1). Check your local code, which may differ.
What is the minimum tread depth?
Under the 2021 IRC, 10 inches, measured from nosing to nosing (R311.7.5.2). Under Approved Document K, a going of 220 mm for a private stair.
How many steps do I need for a 9 foot rise?
A 9 ft (108 in) total rise needs at least 14 risers to stay under the IRC’s 7¾ in maximum, which makes each riser about 7.71 in. An 8 ft rise needs 13 risers of about 7.38 in.
How do I measure total rise?
From the top of the finished floor at the bottom of the stair to the top of the finished floor at the top. If the floors are not finished yet, add the thickness of the flooring that will go down, or your top or bottom riser will come out a different height from the rest.
Why are there fewer treads than risers?
Because the top step is the upper floor itself. A stair with 14 risers has 13 treads; a landing takes the place of one more tread.
How long should the stringer be?
About the hypotenuse of the flight’s rise and run. For 105 in of rise and 130 in of run that is √(105² + 130²) ≈ 167.11 in. Buy a board longer than that so you can cut the plumb and level ends.
Sources
- 2021 International Residential Code, Section R311.7 Stairways (ICC)
- Approved Document K, 2013 edition (GOV.UK)
- NIST: SI units of length
How sources are chosen and checked: editorial policy · these sources in the library, with the other tools that use them